3D regenerative treatment of a referred bone graft failure on the esthetic zone using 2 united non-resorbable Ti-reinforced membranes and a mix autogenous bone from the chin and xenografts 70:30
3D regenerative treatment of a referred bone graft failure. 2 united membranes non-resorbable membranes were used. They were united by mattress resorbable sutures and a bone graft mixing autogenous bone from the chin and bovine hydroxilapatite were placed. 1 year later, Reentry was carried out. Complete bone regeneration of the defect was obtained and 2 implants were placed + a connective tissue graft from the palate in order to gain more volume.
Dr. González
Spain
Seguir a este doctor
Comentarios (3)
Escobar Ruiz, Guillermo
19-02-2018 00:32
Impresionante, como siempre
tengo la misma duda que Berto, porqué optaste por técnica con ROG y membranas
en vez de injerto autólogo tipo Khoury???
enhorabuena una vez más, eres un fuera de serie
el ouchdi, fethallah
18-02-2018 19:33
wow great result nice GBR congrats master
Fernández, Juan Alberto
18-02-2018 14:59
Por dios que bueno eres. Por qué no un khoury?